VBrick Systems 7000 Security Camera User Manual


 
26 © 2009 VBrick Systems, Inc.
There is no chaining of scripts.
Comments are not allowed on the same line as a command.
All scripts are executed in a strictly serial manner by a single task.
While executing a script it is possible to miss a double change of any event.
Passthrough
The TCP/IP network can serve as an intermediary between two VBrick appliances and their
serial ports or between a PC application sending IP packets and an appliance's serial port.
This feature supports a wide range of serial applications. Contact VBrick support for details
and restrictions. End-to-end control is initiated by enabling or disabling Passthrough. For
more about passthrough, and how it can be used, see the H.264 Appliance Getting Started
Guide.
Passthrough State Used to enable/disable Passthrough. You must be the Active Editor to
enter a Passthrough state. Three states are possible:
Disabled – The VBrick will neither initiate nor respond to
Passthrough setup requests.
Responder – In this case the VBrick will accept a connection
request (up to 64 connection requests).
Initiator – In this case it will continuously attempt to automatically
initiate a Passthrough connection to the remote destination. This
mode also offers metadata destination options.