System Configuration
VBrick H.264 Appliance Admin Guide 27
Passthrough State: Responder
Passthrough State Responder – In this case the VBrick will accept a connection request
(up to 64 connection requests).
Baud Rate Rate of Passthrough port. Rate can be set to the following (Default
= 9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400,
19200, 28800, 38400, 57600, 115200.
Stop Bits Number of stop bits for Passthrough port (1 or 2).
Parity None, Even, Odd.
RTS Control Force OFF, Force ON or Automatic. If automatic, the control will be
on when Passthrough is active. Under no conditions are RTS or
DTR controls passed through end-to-end. All control handling is
local. When using a VBrick VCC-3 or VCC-4 camera, set this control
to Automatic; when using a VBrick VCC-50i camera, set this control
to Force ON.
DTR Control Force OFF, Force ON or Automatic. If automatic, the control will be
ON when Passthrough is active. Under no conditions are RTS or
DTR controls passed through end-to-end. All control handling is
local. When using a VBrick VCC-3 or VCC-4 camera, set this control
to Automatic; when using a VBrick VCC-50i camera, set this control
to Force ON.
COM Interface Type Describes the COM interface connector.
RS232 – standard RS-232 serial port connector.
RS422/485 – RS-422/485 4-wire serial port connector.