Detail Settings
3
Picture Recording and output :
triggered by external device
Use this setting to operate the picture
recording function when recording is
performed in conjunction with an external
device such as a sensor or switch.
For a detailed example of actual operation,
see "dPicture Recording User's Guide"
(→ P.1).
"External Device Input 1/2"
Up to 2 recordings from external devices
can be set.
"Recording at ON event"
Tick this option to record pictures when an
"ON" event is detected from an external
device.
"Recording at OFF event"
Tick this option to record pictures when an
"OFF" event is detected from an external
device.
"Pre-event Recording (sec.)"
When you want to record the pictures that
proceeds an ON or OFF event, use this
setting to enter the required number of
seconds.
"Post-event Recording (sec.)"
When you want to record the pictures that
follows an ON or OFF event, use this
setting to enter the required number of
seconds.
"Recording between ON event and OFF event"
Tick this option to record pictures for as
long as an "ON" status continues from the
external device.
"Recording Interval between events"
Records pictures at set intervals between
ON and OFF event. Specify a value
between 1 and 600 seconds as the
sampling interval.
"Camera Position"
Selects the camera angle used when
pictures are recorded. Select "Not
specified", "Home 1" to "Home 4" or
"Preset 1" to "Preset 8".
"Send recorded pictures by e-mail"
You need to make "Mail" settings (
→
P.55)
"Output to External Device 1/2"
Tick this check box when you want to
control output to an external device. Keep
in mind that output to an external device
may not always be possible from Admin
Viewer or WebView Livescope MV Ver.
2.0/2.1.
"Delay following OFF event (sec.)
When controlling output to an external
device and output must retain ON after
input is set to OFF, use this setting to
specify a delay of up to 20 seconds.
"Set operation time"
When you tick this option, input from an
external device is limited to the operation
time specified below. Enter the start time
and end time for the intervals during
which external input is acceptable.
"Handle ON/OFF input in reverse"
On some devices, ON and OFF are
reversed. Use this setting for such devices.
External Device Common Settings
When using WebView Livescope MV Ver. 2.1 (sold
separately → P.16), if these settings are made, all
names will be applied to MV. Since these settings are
not applied to the viewers (→ P.6), these settings are
only required if MV is used.
"External Device Input 1/2"
"External Device Input Name"
Enter on external device input name consisting of up to
15 alphanumeric characters.
"External Device Output 1/2"
"External Device Output Name"
Enter on external device output name consisting of up
to 15 alphanumeric characters.
Detail Settings
48
e
Tip
Use the Motion Detection Setting Tool (→ P.80)
for picture recording and external device
control based on motion detection.