Chassis Description 27
Server Management Summary
The server board’s server management architecture features a board management controller (BMC),
which autonomously monitors server status and provides the interface to server management
control functions. The BMC is responsible for controlling system power, resets, monitoring
voltages, temperatures, fans, and communicating with secondary controllers on its Intelligent
Platform Management Bus (IPMB).
The functions of each controller are summarized in the following sections.
Server Board Management Controller
The BMC on the server board provides server management monitoring capabilities. Associated
with the BMC is a flash memory that holds the operational code, sensor data records (SDR), and
system event log (SEL). A serial EEPROM holds the BMC configuration defaults and field
replaceable unit (FRU) information. The BMC supports the following:
Server board voltage monitoring
Fan failure detection
Fan speed control
Processor voltage monitoring
Processor presence detection
Processor internal error (IERR) monitoring
Fault resilient booting (FRB)
Processor disable control
Watchdog timer
Periodic system management interrupt (SMI) timer
I
2
C master controller for the Intelligent Platform Management Bus (IPMB)
Three private I
2
C management bus interfaces
Server management software (SMS) and server management mode (SMM) IPMB message
receiver
Event message receiver
System event log (SEL) management and access
Sensor data record (SDR) repository management and access
Processor nonmaskable interrupt (NMI) monitoring
Processor SMI monitoring
Time-stamp clock
Secure mode, video blank, and floppy write protect
Software front panel NMI generation