Specifications
Power supply: AC 100 V to 240 V, 50/60 Hz
Power consumption: Approx.
40 W
indicates safety information.
GENERAL
Operating temperature: 32 °F to 104 °F (0 °C to +40 °C)
Storage temperature: –4 °F to 122
°F (–20 °C to +50 °C)
Allowable humidity ranges: Less than 85 % (no condensation)
Weight: Appro
x.
16.5 lbs. (7.5 kg)
Dimensions (W D H): 9-3/8˝ 10-1/8˝ 13-1/2
˝ (238 257 343.5 mm) [excluding protrusions]
Finish: Light silver matte finish
Contr
oller supported: AW
-RP655, AW-RP555, AW-RP400, AW-IF400, AW-CB400
It ma
y be necessary to upgrade the version of the controller so that the controller will
support the unit.
INPUT
Input connector: AC 100 V to 240 V (50/60 Hz),
G/L IN (BNC)
BBS or VBS signal supported
OUTPUT
Output connector: Composite: 1.0 Vp-p/75 (BNC 1),
HD/SD analog component or SD Y/C signals (VGA 15P 1)
Y/C signals av
ailable in SD mode only; switching with Y/Pb/Pr signals possible
using menu setting
SD/HD selection possible when Y/Pb/Pr signals are output.
INPUT/OUTPUT
Input/Output connector: CONTROL IN RS422A (RJ-45)
FUNCTIONS AND PERFORMANCE
[Camera unit]
Imaging sensors: 1/3˝ CCD imaging sensors 3 (inter-line type, progressive system supported)
Lens: Motoriz
ed 13 zoom, f/1.6 to 2.8
(f=4.2 to 55 mm; 35 mm equivalent: 32.5 mm to 423 mm)
Focus: Switching between auto and man
ual
Color separation optical system: Prism system
Gain selection:
0 to 12
dB in step, 15 dB,
18 dB, AGC (iris always operated automatically at the AGC ON setting)
Electronic shutter speed:
1/100, 1/250, 1/500, 1/1000, 1/2000 sec.,
Synchro scan (60.04 to 248.82 Hz)
Gamma: Low
, Normal, High