47
Viewing and Setting the Viewfinder Displays
Chapter 3 Basic Adjustments and Settings
Example: Box cursor
Activating/deactivating the cursor
indication
The <CHAR/MARK MIX> page of the USER
(OPERATION) menu permits you to activate/deactivate
the cursor indication for each output.
<CHAR/MARK MIX> page
The CURSOR indication is deactivated for all the outputs
at the factory.
Setting the type and size of the cursor
For the outputs for which you activate the cursor indication
on the <CHAR/MARK MIX> page, select and adjust the
cursor to be displayed on the next <MARKER SETTING>
page.
<MARKER SETTING> page
3-6-8 Checking the Power Voltage
The settings of the NEAR END and END values to warn
of low voltage of a power supply can be checked on the
<BATTERY ALARM> page of the USER (OPERATION)
menu.
<BATTERY ALARM> page
This page is intended for display only. You can only switch
the type. If you want to change the values, use the <BATT
ALARM SET> page of the MAINTENANCE menu.
Menu item Function
VF1 Turn the cursor indication on the viewfinder
connected to the VF1 connector on/off.
VF2 Turn the cursor indication on the viewfinder
connected to the VF2 connector on/off.
MONITOR Turn the cursor indication on the monitors
connected to the MONITOR OUT
connectors on/off.
<CHAR/MARK MIX> U09
VF1 VF2 MON1 VBS
CHAR : ON ON ON ON
MARKER : ON ON ON ON
CURSOR :
B
OFF OFF OFF
ZEBRA : OFF OFF OFF OFF
VF GATE MARKER: OFF
<MARKER SETTING> U03
CENTER : OFF 1
SAFETY : OFF 90.0%
EFFECTIVE : OFF
ASPECT : OFF 4:3
VARIABLE : --
SAFETY : OFF 90.0%
MASK : OFF 12
CURSOR :
B
BOX
POSI H/V : 0 0
SIZE W/H : 960 540
Menu item Function
CURSOR Select the type (BOX/CROSS) of the cursor
to be displayed.
POSI H/V Adjust the H (horizontal) position (–958 to
956) and the V (vertical) position (–538 to
536) of the center.
SIZE W/H Adjust the width (from the center to right or
left side) (16 to 1920) and the height (from
the center to top or bottom) (16 to 1080) of
the cursor.
Menu item Indication
DC IN (24V) Voltage of the 24-V power
TYPE Select the type of the 24-V power source.
NEAR END NEAR END value specified for the 24-V
power source of the selected type
END END value specified for the 24-V power
source of the selected type
DC IN (12V) Voltage of the 12-V power
TYPE Select the type of the 12-V power source.
NEAR END NEAR END value specified for the 12-V
power source of the selected type
END END value specified for the 12-V power
source of the selected type
<BATTERY ALARM> U15
DC IN (24V) 24.2V
TYPE:
B
AC ADP
NEAR END : (22.2)
END : (21.6)
DC IN (12V) 12.8V
TYPE:
AC ADP
NEAR END : (11.1)
END : (10.8)