Sony F35 Camcorder User Manual


 
75
Menu List
Chapter 4 Menu Configuration and Detailed Settings
<OUTPUT
FORMAT>
Setting the output
video format
M07
[M03]
CURRENT 23.98PsF 4:4:4 The current format is
displayed.
SCAN PROGRESSIVE PROGRESSIVE,
INTERLACE
When INTERLACE is
selected for SCAN, select
half the value of the field
frequency in FRAME.
FRAME 23.98 23.98, 24, 25, 29.97, 30,
50, 59.94, 60
SIGNAL 4:4:4 RGB 4:4:4 RGB, 4:2:2 YCbCr
SELECT FPS OFF ON, OFF
SET FORMAT Execute by ENTER.
<DOWN
CONVERTER>
Setting the aspect
ratio for VBS output
M08
[M04]
ASPECT LB SQ, LB, EC SQ: Squeeze
LB: Letter Box
EC: Edge Crop
<POWER SAVE>
Selecting the output
power save mode
M09
[M05]
MONITOR OUT ACTIVE PWR SAVE, ACTIVE
DOWN CONVERTER ACTIVE PWR SAVE, ACTIVE
<BATT ALARM
SET>
Setting the voltage
values to trigger
alarm indications
M10
[M06]
DC IN (24 V)
TYPE AC ADP BATT1, BATT2, AC ADP BATT1/BATT2: Batteries
AC ADP: AC adaptor
NEAR END 22.2 V 0.1 to 30.0 V Fixed to the default value
for AC ADP
END 21.6 V 0 to 29.9 V Fixed to the default value
for AC ADP
DC IN (12 V)
TYPE AC ADP BATT1, BATT2, AC ADP BATT1/BATT2: Batteries
AC ADP: AC adaptor
NEAR END 11.1 V 11.0 to 17.0 V Fixed to the default value
for AC ADP
END 10.8 V 10.5 to 14.0 V Fixed to the default value
for AC ADP
<GENLOCK>
Adjusting Genlock
with status
indications
M11
[M07]
REFERENCE INTERNAL, GENLOCK
IN
display only
STATUS OK, NG, NO SIGNAL display only
H PHASE 0 –511 to 511 To adjust the H phase for
genlock
<DATE>
Setting the built-in
clock
M12
[M08]
DATE/TIME yyyy/mm/dd
hh : mm
MAINTENANCE menu
Page title &
purpose
No. Item Default Settings Remarks