VBrick Systems VB6000 Security Camera User Manual


 
Command Line Interface
VBrick Appliance Getting Started Guide 57
CLI Examples
The following examples show various VBrick configuration tasks. User input commands are
shown in bold text; VBrick responses are non-bold. Example 1 shows the entire command
sequence used to set a parameter, including how to login and begin and end an edit session.
For clarity, the other examples are abbreviated and show only the actual get and set commands.
Remember that you only need to begin an edit session at the start of an edit session or if
someone has ended your edit session. You only need to end an edit session when you are
done, and after you have applied or saved your changes.
Example 1 – Set Variable
T To enable Slot1 Transmit:
1. Login to the appliance.
Login: <username>
Password: <password>
2. Start an edit session.
VBrick> SVAR vbrickEditName=
VBrick> SVAR vbrickEditName=<username>
3. Make your changes.
VBrick> SVAR vbrickSlot1EncoderNetworkTransmitEnable=2
$!vbrickSlot1EncoderNetworkTransmitEnable=2
VBrick> SVAR vbrickSlot1EncoderNetworkApplySet=2
$!vbrickSlot1EncoderNetworkApplySet=2
4. Save the configuration.
VBrick> SVAR vbrickSysSaveConfiguration=2