Diagnostic
error
codes
For
information
on
running
the
diagnostic
programs,
see
“Starting
the
AMIDiag
program”
on
page
38.
System-error
codes
Error
Code/Symptom
FRU/action
3000h
(Register
Bank
Switch
Failed
.)
1.
Reseat
all
microprocessors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3001h
(Register
Read/Write
Failed
.)
1.
Reseat
all
microprocessors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3002h
(CPU
Basic
Instruction
Operation
Failed.)
1.
Reseat
all
microprocessors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3003h
(CPU
Parallel
Data
Manipulation
Failed.)
1.
Reseat
all
microprocessors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3005h
(FPU
Arithmetic
Error.)
1.
Reseat
all
microprocessors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3006h
(FPU
Comparison
Error.)
1.
Reseat
all
processors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3007h
(FPU
Load/Store
Error.)
1.
Reseat
all
microprocessors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3008h
(FPU
Conversion
Error.)
1.
Reseat
all
microprocessors
and
power
modules.
2.
Individually
replace
microprocessors
and
power
modules.
3.
Processor
board.
3010h
(CPU
Speed
does
not
match
expected
value.)
1.
Check
that
the
expected
value
entered
is
correct.
2.
Reseat
all
microprocessors
and
power
modules.
3.
Individually
replace
microprocessors
and
power
modules.
4.
Processor
board.
3100h
(Read/Write
test
on
DMA
controller
1
failed.)
I/O
board
3101h
(Read/Write
test
on
DMA
controller
2
failed.)
I/O
board
3102h
(Read/Write
test
on
page
registers
failed.)
I/O
board
3140h
(Battery
backup
unit
that
powers
CMOS
RAM
has
no
power.
)
Battery
or
CMOS
unit
Chapter
6.
Symptom-to-FRU
index
159