IBM 8688 Security Camera User Manual


 
Table
10.
Memory
test
error
codes
(continued)
Error
code/symptom
FRU/action
9307-xxx-00-00
(Test
Aborted:
Choppiest
Internal
Error.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
reflash
the
diagnostic
code.
9308-xxx-00-00
(Diagnostic
Program
Error.
Test
Aborted:
No
DIMMs
installed.)
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
reflash
the
diagnostic
code.
9309-xxx-00-00
(Test
Aborted:
Fast
Scrub
Error.)
1.
Reload
the
system,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
replace
the
memory
board.
9310-xxx-nn-nn
(Test
Failed:
ECC
errors.)
nn=
the
DIMM
connector
designation,
1-28.
1.
Restart
the
server,
and
run
the
test
again.
2.
If
the
symptom
still
exists,
replace
the
DIMMs.
LED
error
codes
Table
11.
LED
error
codes
Error
code/symptom
FRU/action
9001-180-xxx-xxx
(Failed
Front
LED
panel
test.)
1.
Light
Path
Diagnostics
card
2.
Power/reset
card
assembly
3.
Midplane
board
4.
I/O
board
9002-180-xxx-xxx
(Failed
Memory
Board
LED
test.)
1.
Memory
board
2.
Midplane
board
9003-180-xxx-xxx
(Failed
Active
PCI
LED
test.)
PCI-X
board
9004-180-xxx-xxx
(Failed
Diagnostics
LED
test.)
1.
Light
Path
Diagnostics
card
2.
Midplane
board
9005-180-xxx-xxx
(Failed
Fan
LED
test.)
1.
Fan
2.
I/O
board
9006-180-xxx-xxx
(Failed
Centerplane
LED
test.)
Midplane
board
9007-180-xxx-xxx
(Failed
I/O
board
LED
test.)
I/O
board
9008-180-xxx-xxx
(Failed
SCSI
Backplane
LED
test.)
1.
SCSI
backplane
cable
2.
SCSI
backplane
3.
Midplane
board
Table
12.
LED
error
codes
for
the
RXE100
port
Error
code/symptom
FRU/action
9021-180-xxx-xxx
(Failed
RXE
Operator
panel
LED
test)
1.
RXE
Operator
panel
cable
2.
RXE
Operator
panel
3.
RXE
backplane
9022-180-xxx-xxx
(Failed
RXE
PCIXBackplane
Side
A
LED
test)
1.
RXE
PCI-X
backplane
(Side
A)
2.
RXE
backplane
Chapter
6.
Symptom-to-FRU
index
175