Kowa nonmyd WX 3D Digital Camera User Manual


 
40
10.7 Replacing ash lamp / 10.8 Fuse replacement /
10.9 Relling and replacing consumables
10.8 Fuse replacement
Warning
Unplug
Warning
High-Voltage
When replacing the fuse, make sure the instru-
ment is turned OFF and unplugged from the
power outlet.
If the fuse holder
cover is removed with the in-
strument unplugged, there may occur electrical
shock.
Warning
Obligatory
Use a designated fuse only.
Otherwise, the instrument may malfunction or a re may break
out.
1
T
urn OFF the power switch and pull the plug from the power outlet.
2
Make sure that the instrument is turned OFF and wait for discharge at least 5 minutes for safety.
3
Press
down the fuse holder with a screwdriver and turn the fuse holder to the direction of the arrow (counterclockwise)
for removal.
4
Pull the old fuse and
replace it with a new one. Make sure that the fuse
type and rating are correct.
5
Press down the fuse holder
with a screwdriver and turn the fuse holder to
the opposite direction of the arrow (clockwise) and install it in place.
6
Connect the power cable plug to an power outlet.
10.9 Relling and replacing consumables
Order spare parts by purchase order numbers listed below to Kowa or your Kowa dealer.
Part name Purchase order number
Flash lamp K9L39FU
Fuses
21802.5M
(T2.5AL250V)
Chin rest paper K9L-TB45#102
Chin rest paper retaining pin K9L-TB45#101
Dust cover AFT2#179