ASSEMBLY INSTRUCTIONS
20
Lens replacement has to be carried out in a clean and dust-free environment.
Avoid the soiling of the internal parts of the camera. Do not touch the internal
parts of the camera while the lens is removed.
If extension rings are used, please do not connect or disconnect the lens from
the ring as long as the extension ring is attached to the camera.
Always remove the extension ring from the camera first, and then
remove the lens from the ring.
5.3 Attachment and Removal of the Sinarback
When your Sinar Hy6 camera is delivered, the back is already attached to the camera. The
following descriptions should be observed if a back has to be removed or attached.
With the following Sinar Hy6 systems, a back is delivered:
Sinar Hy6-e75 – delivered with a Sinarback e75 LV
Sinar Hy6-e54 – delivered with a Sinarback e54 LV
Sinar Hy6-m54 – delivered with a Sinarback 54 MC
5.3.1 Attachment and Removal of the Protective Cover
If you have ordered only a Sinar Hy6 camera body, the back has to be attached before
you start to operate the camera.
When a Sinar Hy6 system is transported or
stored without an attached Sinarback, the
protection cap has to be attached to the
camera body to protect the internal parts of
the camera.
Before you attach the Sinarback, please
remove this protection cap from the camera
body. Press the Adapter Release Button 1
and push it upwards. To replace the
protective cover, insert the four pins into
the respective holes and attach the
protective cover.
Fig. 5 / 11 Protection cover