4
Chapter 4 Adjustments and Settings for Recording 4-39
4-5-4 Synchronizing the Time Code
You can synchronize the internal time code generator of this camcorder
with an external generator for the regeneration of an external time code.
You can also synchronize the time code generators of external VTRs
with the internal generator of this camcorder.
Connections for time code synchronization
Connect both the reference video signal and the external time code as
illustrated below.
Example 1: Synchronizing with an external time code
GENLOCK IN
Reference video signal
a)
TC IN
External time code
a) In addition to the HD-Y signal, the NTSC
composite video signal can be input as the
reference video signal.