Sony SAL35F14G Camera Lens User Manual


 
4-32
SAL35F14G (1.4/35G) (35mm F1.4G)
4) When the Near position check finishes normally, the message “Move FOCUS to Infinity position at about 5sec.” is displayed on the
pop-up window.
Set the focus to the infinity position and press down the ENTER key.
Fig.4-7-18
5) When the infinity position check finishes normally, “OK” is displayed on the pop-up window, and press the ENTER key to return to
the initial window.
Fig.4-7-19
3. In case of error display in the Focus Pattern (near position)
1) When the error display and the NG display appear to the pop-up window, press the ENTER key to return to the initial window, and
perform “2. Checking Method”again.
Fig.4-7-20
Fig.4-7-21
2) Although the lens is positioned at the near position, if “NG” appears, confirm or perform the following.
4-7-1. Focus Brush Position Check (Search Focus Adjustment Point)
Cleaning of flexible pattern or the brush.
Replaceing the brush.
Rotating operation error of the focus ring (rotation speed is not suitable at a regulated speed.).
3) Perform “2. Checking Method”again, repeat the inspection until “OK” appears on the pop-up window.