Sony SAL35F14G Camera Lens User Manual


 
4-36
SAL35F14G (1.4/35G) (35mm F1.4G)
4-9. WRITE dSB
Equipment
Personal Computer
Finished Inspection JIG
Lens Adjustment Program (ActuatorChecker.exe)
1. Preparations
1) Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2) Start up of ActuatorChecker.exe.
3) Click [Set up], and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1) Click the [Write dSB].
Fig.4-9-1
2) The Serial window appears. Input the lens serial number.
Note:
When
[OK]
is clicked without inputting the serial number, the date executed is displayed on the completion window of each item.
Fig.4-9-2
3) The Select dsb window appears.
4) Being based on the image point shift amount calculated by 4-5. FOCUS-SHIFT CHECK/ADJUSTMENT (APERTURE (AMOUNT
OF SPHERICAL ABERRATION)), select the button.
Fig.4-9-3
5) When the Write dSB finishes normally, OK appears on the pop-up window.
Fig.4-9-4