Fujitsu M8000 Security Camera User Manual


 
ioxadm(8)
System Administration 65
NAME ioxadm - manage External I/O Expansion Units
SYNOPSIS ioxadm [-f][-p][-v][-M] env [-e][-l][-t][ target [ sensors]]
ioxadm [-f][-p][-v][-M] list [ target]
ioxadm [-f][-p][-v][-M] locator [on|off] [ target]
ioxadm [-f][-p][-v][-M] poweroff target
ioxadm [-f][-p][-v][-M] poweron target
ioxadm [-f][-p][-v][-M] reset target
ioxadm [-f][-p][-v][-M] setled [ on|off|slow|fast] target led_type
ioxadm -h
DESCRIPTION ioxadm(8) manages External I/O Expansion Units and link cards attached to the
system.
For this utility, an operand with parameters and a target device must both be
specified. The target device can be a downlink card mounted in a built-in PCI slot
in the host system; an External I/O Expansion Unit; or a field replaceable unit
(FRU) in an External I/O Expansion Unit. The downlink card is identified by a
string which identifies the host path to the card. An uplink card is a FRU in the
I/O boat.
Privileges You must have one of the following privileges to run these commands:
Refer to setprivileges(8) for more information.
OPTIONS The following options are supported.
Required Privileges Commands
platop env, list
platadm locator, poweroff, poweron
fieldeng reset, setled
-f Forces command execution by ignoring warnings.
-h Displays usage statement.
When used with other options or operands, an error occurs.