Operating Your SDI Video Matrix Switcher
23
The MATRIX Display shows the identical 2 non-blinking digits
(representing that input number) for all outputs.
7.2.3 Clearing
1
Outputs
You can clear (delete):
One output (see section 7.2.3.1)
Several outputs (see section 7.2.3.2)
All outputs (see section 7.2.3.3)
7.2.3.1 Clearing One Output
To clear an output (in the AT ONCE mode):
1. Press the appropriate OUT button.
The MATRIX Display shows the 2 blinking digits, representing the present
input number for that specific output
2
. If the present input is clear, the 2
blinking digits 00 appear in the MATRIX Display.
The STATUS Display shows the message:
out # x
Where x is the output number
2. Press the OFF button
3
.
The input is cleared and the MATRIX Display does not show any Input # in
its place.
The STATUS Display momentarily shows the message:
out # x
reset
Where x is the output number
To clear an output (in the CONFIRM mode (the TAKE LED is lit)):
1. Repeat step 1 above.
2. Press the OFF button
3
.
The MATRIX Display shows the 2 blinking digits 00 instead of the
previous 2 blinking digits and the TAKE LED blinks.
The STATUS Display shows
4
the message:
out # x
reset
1 “Clearing” means disconnecting the output from any of the inputs, and leaving it disconnected
2 For example, pressing OUT button 9 shows the blinking digits 01 if input 1 was previously routed to OUT 9
3 You can press the OFF button first, and then an OUT button (the order is irrelevant)
4 Continuously, within the limit of the timeout (approximately 30 seconds)