Kramer Electronics VS-1616SDI Camcorder User Manual


 
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Operating Your SDI Video Matrix Switcher
26
7.2.4.1 Storing Setups
To store a setting, do the following:
1. Press the STO button.
The Displays show the messages:
Enter SETUP number
use two digit # 01-99
Store
# xy
Where xy are the OUT buttons.
2. Press two OUT buttons, using the OUTkeys # 1 to 9, and 10 (for 0).
The OUTkeys function on a decimal-basis, and not on a positional-basis.
For example, to enter the # 14, press # 1 followed by # 4 (not # 14). To enter
the # 3, press # 3 followed by the TAKE button
1
.
The TAKE LED blinks and the Displays show the messages:
STORE this SETUP ?
YES -> TAKE
Store
# xy
3. Press the TAKE button.
The memory stores the setup and the MATRIX Display shows the
message:
Setup # xy stored
Note, saving a setup to an already allocated setup #, prompts the message in
the MATRIX Display:
Setup already exists
Press TAKE to overwrite
Pressing the TAKE button replaces the stored setup with the current setup.
Alternatively, press a different OUT button to change the setup #.
7.2.4.2 Recalling Setups
To recall a setting, do the following:
1. Press the RCL button.
The Displays show the messages:
Enter SETUP number
use two digit # 01-99
RECALL
# xy
where xy are the OUT buttons.
2. Press the appropriate two OUT buttons, using the OUTkeys # 1 to 9, and 10
(for 0). The OUTkeys function on a decimal-basis, and not on a positional-
1 Alternatively, pressing # 10 followed by # 3 will also enter the # 3