18
HDR 24/96
HDR 24/96
I/O Card 17-
24
24- bit Analog
ADAT
ADAT
Apogee DIO
AES-EBU
Setup
Setup AES Card - Slot 3
Pro
Pro
Stadus Bits:
Pro
Pro
Consumer
Pro
Sample Rate Conversion:
1- 2 Converted
3- 4 Converted
5- 6 Converted
7- 8 Converted
Optimal settings are - NOT converted and Pro.
1. Select Setup from the Windows menu (or use keyboard
shortcut CTRL+1).
2. Click on the Digital I/O icon. For each PDI•8 card, click
the Setup button. In the AES/EBU Setup dialog, check
the Converted boxes corresponding to the desired
input(s) to enable sample rate conversion; leave the
boxes unchecked for no sample rate conversion
(default).
3. Then select Pro (default) or Consumer from the
pulldown menus associated with the desired output(s).
Click the arrow in the top right corner of the dialog or
hit ESC to exit.
Note: Note:
Note: Note:
Note: When sample rate conversion is active, the input signal is truncated to 20
bits, causing a slight degradation in the signal quality of a 24-bit input. Therefore
sample rate conversion should be enabled only when intentionally converting a
signal to a different sample rate (e.g. from 44.1k to 48k), or when no other means
exist to establish clock synchronization with the device(s). See the Reference
Manual for details.