Installation
Internal PSII
28
45537L-005 ZebraNet PrintServer II User Guide 04/21/2009
To install an internal PSII into a XiII, XiIII, R140, 105SL, and PAX Series printer,
complete these steps:
1.
2.
3.
From the back of the printer, remove the two screws and the blank cover plate positioned
next to the main RS-232 and parallel interface connectors.
4. Which printer model do you have?
Caution • A qualified service technician must perform this installation.
Tools • You need these tools to complete this procedure:
Phillips Screwdriver Set 3/32 in. Allen Wrench
Caution • Observe proper electrostatic safety precautions when handling
static-sensitive components such as circuit boards and printheads.
Connect yourself to an antistatic device.
Caution • Turn off (O) the printer and disconnect it from the power source before
performing the following procedure.
Turn off (O) the printer and disconnect the AC power cord and all data cables.
If you have
a(n)…
Then…
XiII, XiIII series,
R140, or a 105SL
a. See Figure 5.
b. To remove the side panel, remove the screws and remove the
left side panel.
PA X
a. See Figure 6.
b. To remove the side panel, access the electronics by removing
the mounting screws from the printer’s PCB access panel and
sliding the panel out.