Kodak 2400DSV Photo Scanner User Manual


 
Function Mode and Adjustment
6
93
6.7.3 o3: P-P Auto Exposure Coarse Adjustment
This adjustment is made when the image density on the print (scan)
output in the Auto Exposure mode is not satisfactory.
This adjustment is necessary after the replacement of PWB-A and PWB-
BB.
1. Turn the Power Switch, set the Auto Exposure Mode into Auto and
select the center position of exposure level.
2. Make a print (scan) and check the image density.
<Conditions of printing/scanning>
Print Mode .............Text
Film Type ................Posi
3. Refer to the charts given below.
Then, adjust to desired image density by Function Mode o3.
o3
Setting Function Image density
d4 4 step lighter Lighter
Darker
d5 3 step lighter
d6 2 step lighter
d7 1 step lighter
d8 Standard
d9 1 step darker
dA 2 step darker
db 3 step darker
dC 4 step darker
Be sure to adjust the Projection Lamp Voltage (F7) and
Shading Correction (b6) before this Adjustment.