Kodak 2400DSV Photo Scanner User Manual


 
Troubleshooting
7
113
7.5 Troubleshooting for malfunction
7.5.1 No Power
7.5.2 The Projection Lamp does not Light Up
Check Item Remedy
Has the Power Switch (S1) been
turned ON?
No Turn on the Power Switch (S1).
Yes
Has the Power Cord been securely
connected to the machine?
No Plug in the power cord.
Yes
Has the Power Cord been securely
plugged into the outlet?
No Plug the power cord into the power
outlet.
Yes
Is the Fuse (F1) blown?
Yes Replace Power Fuse (F1).
No
Is the Interlock Switch (S201) in the
actuated position when the Projection
Unit is installed?
No Adjust the position of the Switch (S201).
Yes
Is the Fuse of PU1 blown?
No Replace PU1 or S201.
Yes Replace Fuse(F1) of PU1.
Check Item Remedy
Check LA1.
NG
Replace LA1.
OK
Check TS1.
NG
Replace TS1.
OK
Is the voltage across CN7-1 and -2 approx.
DC17V when the Power ON/OFF switch is
in the ON position?
No
Check wiring.
Yes
Is the source voltage developing across
PJ1-1 and -3 on PU2 when the Power ON/
OFF switch is in the ON position?
No
Check wiring.
Yes
Is the voltage across PJ3-1 on PU2 and
GND DC5V when the Power ON/OFF
switch is in the ON position?
No
Check wiring.
Yes
Replace PWB-BB.
Replace PU2.