Renesas RX700 Camera Accessories User Manual


 
PG-FP5 V2.13 PROGRAMMING GUI USAGE
R20UT2924EJ0200 Rev.2.00 Page 19 of 71
Mar 02, 2015
Figure 1.22 [Open firmware file] Dialog Box
Select the firmware file “fp5_fw_vxxx.rec” and then click the Open button.
Note 1. Do not use FP5 firmware other than the one posted on the website; otherwise, a defect may occur.
2. When a firmware of FP5 updates from V2.00 to V1.xx, a serial number of FP5 is erased.
And, FP5 can't operate in USB1.1. In addition, the other functions don't have any problem.
When FP5 revives, consult a Renesas Electronics sales representative or distributor.
Some commands are sent to the FP5 and the update progress status is displayed in the action log window. The message
“Firmware Update succeeds”, which indicates normal completion of firmware update, and “Restarting FP5...”, which is
equivalent to [RESET] command processing, is automatically performed. The new version can then be checked as
“Firmware Version Vx.xx”. The update takes about 10 seconds.