PG-FP5 V2.13 PROGRAMMING GUI USAGE
R20UT2924EJ0200 Rev.2.00 Page 29 of 71
Mar 02, 2015
(3) [Program] command
The [Program] command transmits the memory contents (program files) in the FP5 valid programming area to the target
device and writes the programs to the flash memory. The target area can be set in the [Operation Area] area on the
[Advanced] tab in the Device Setup dialog box. The progress status of this command is displayed as a percentage in the
action log window. When execution of this command is completed, the programming GUI displays the result of
command execution in the target device. Command options after execution of this command depend on the following
settings on the [Standard] tab or [Advanced] tab in the Device Setup dialog box.
[Run after Disconnect] check box
[Set OFS after Program] check box
[Set ID code after Program] check box
[Set Commad Protection after Program] check box
[Disable Serial Programmer after Program] button
[Set Option bytes after Program] check box
[Checksum after Program] check box
[Set Endian after Program] check box
[Verify after Program] check box
[Set Lock bit after Program] check box
[Set OTP after Program] check box
[ICU validate after Program] check box
For details, refer to 1.3.3 (14) (b) or (c).
(4) [Verify] command
The [Verify] command verifies the memory contents (program files) in the FP5 valid programming area against the data
written to the flash memory in the target device, and receives the result. The target area can be set in the [Operation
Area] area on the [Advanced] tab in the Device Setup dialog box. The progress status of this command is displayed as a
percentage in the action log window. When execution of this command is completed, the programming GUI displays
the result of command execution in the target device.
(5) [Read] command
The [Read] command loads data on the flash memory in the target device and saves it as a file. The target range of the
flash memory is specified in the [Operation Area] area on the [Advanced] tab of the Device Setup dialog box. When the
[View] command is executed following this command, 4 KB read data is displayed in the log window each time the
ENTER key is pressed. When the [Write Intel HEX file] or [Write Motorola SREC file] command is executed
following this command, the read data can be saved in the Intel HEX format or Motorola HEX format. Use of the
saved file with other tool products is not supported.
Note The folder in which program data was saved the last time is displayed in the program data save dialog box.
Note When you execute the [View] command, if a 16-byte-aligned range contains blank areas and data areas, the
blank areas are indicated by '**'.