Sony HSR-X200 Security Camera User Manual


 
39 (GB)
Settings
To activate series recording, set each of the connected
HSR-X200/X200P units as follows with 4.
RECORDING CONDITIONS SET of MAIN MENU
1.
For details on menu operations, see “Menu Operations” on
page 17(GB).
<RECORDING CONDITIONS SET>
SERIES RECORDING : OFF
NORMAL RECORDING AREA
OVERWRITE : OFF
ALARM RECORDING AREA
OVERWRITE : OFF
REMAINING DISK WARNING : 1%
Set SERIES RECORDING to ON.
Set OVERWRITE to OFF for both NORMAL
RECORDING AREA and ALARM RECORDING
AREA.
For details on OVERWRITE, see “Recording Area Settings”
on page 46(GB).
Notes
• Series recording cannot be performed if timer
recording has been specified.
Be sure that the TIMER button indicator is dark on
all the connected HSR-X200/X200P units.
• If the OVERWRITE function is set to ON on any of
the connected HSR-X200/X200P units, recording
will be continued on that unit.
To start series recording
Press the z REC button on the first HSR-X200/
X200P.
Multiplexer Connection and
Associated Settings
Connection example
Settings
Specify the type of the connected multiplexer with
2. VIDEO INPUT/PRE REVERSE of MAIN MENU
1.
For details on menu operations, see “Menu Operations” on
page 17(GB).
<VIDEO INPUT>
MULTIPLEXER : NO USE
<PRE REVERSE PLAY>
PRE REVERSE PLAY TIME : 10 MIN
SONY: Sony-made multiplexer (YS-DX516, etc.)
OTHERS1: Sanyo-made multiplexer
OTHERS2: Multiplexer of other manufacturers,
including Dedicated Micro and Robot
NO USE: Not to use any multiplexer
PC CARD
MIC
AUDIO
IN
IN
OUT
OUTLOOP OUT IN OUTLOOP OUT
RS-232C
S-VIDEO VIDEO
IN INOUT OUT
WARNING OUT
CLOCK
NON REC OUT
ALARM
RESET
FULL
ALARM
FULL
ON
RS485
TERMINATE
OFF
COMCOM
AB
INOUTCOM COMCOMCOM COM
REMOTE
RS485
SERIES
SW OUT
-AC IN
VIDEO
OUT
ALARM
COM
+ OUT
SW OUT
+ COM
VIDEO
IN
ALARM
COM
+ IN
SW+ C
AL
VCR INVCR OUT
HSR-X200/X200P
Multiplexer
to an AC outlet