Axis Communications 2100 Security Camera User Manual


 
Technical Specifications AXIS 2100 User’s Guide
54
Appendix E - Technical Specifications
System Requirements - TCP/IP on Windows 95, 98, NT and 2000, as well as Linux, UNIX,
Mac and several others. Microsoft Internet Explorer 4.x, or higher (used with Axis’ ActiveX
component AXIS Camera Control), or Netscape 4.x or higher.
Network Connection - RJ45 twisted pair cable, or remote connection using any standard serial
modem.
Networking - 10baseT Ethernet or 100baseTX Fast Ethernet, TCP/IP, HTTP, FTP, SMTP,
NTP, ARP and BOOTP.
I/O Connector - 1 optical-isolated alarm input. 1 digital output (max 24V, 100mA) with
programmable digital input/output for remote image storage via FTP or SMTP, pre/post alarm
image storage.
Image Updating - Up to 10 frames/second over 10Mbps or 100Mbps networks.
Pre/Post Alarm Buffer - Up to 500kB memory available for pre/post alarm image storage.
Modem Connector - Single 9-pin D-SUB RS-232 connector, max 115 kbps, half duplex
Operating Conditions: - Temp: 40
o
to 105
o
F (+5
o
to +40
o
C), Humidity: 20-80% RHG.
Approvals - EMC: FCC Class A, EN 55022/1994, EN55024/1998
Safety: EN 60950, UL, CSA.
Metrics: - Height: 1.6” (4.3 cm), Width: 4.0” (10.2 cm), Length: 5.8” (14.7 cm), Weight: 0.55
lb. (0.25 kg) excluding power supply.
Hardware - ARTPEC-1 compression chip; ETRAX-100, including, 32 bit RISC, 100 MIPS
CPU, 8 MB RAM, 2 MB FLASH PROM.
Power - External power supply 12V AC, 9.6 VA (PS-D, included), 9-15V AC, min. 10VA, or
9-15V DC, min. 7W.