JAI TM/TMC-4200CL Security Camera User Manual


 
Page 10
Graphical User Interface
Dual-Tap TM-4200CL AccuPiXEL Series Camera-Control Software
FIGURE 13. Trigger mode uses a manual or sensor command to operate the shutter.
FIGURE 14. To use Programmable shutter speed, select Programmable:
3.3.2 (b) Expo (lines)
The Expo (lines) selection of the Exposure Control frame determines how long the shutter remains
open, since a certain amount of time is allotted to expose each line. A minimum of one line of pixels
must be exposed. The maximum number of lines is 2079 in Trigger mode. Continual mode is limited to
the size of the frame. Enter the number of lines desired either by clicking on the arrows in the interface,
or by inputting a number directly into the box beside the “Expo (lines)” box.
3.3.2 (c) Scan Area
Changing the scan area affects the image resolution. If desired, the size of the scan area can be selected
from the drop-down list box. When the Scan Area setting is used to designate the number of lines, the
rest of the Exposure Control frame is disabled.