JAI TM/TMC-4200CL Security Camera User Manual


 
Page 46
Functions and Operations
TM/TMC-4200CL Series Progressive Scan Cameras
6.6 External Sync and Pixel Locking
The TM-4200CL accepts an external sync of standard HD and VD at TTL level for general locking to a
system sync and clock. The frequency requirement is as follows:
Full Progressive Scan:
fHD = 30.769 KHz ± 2%
fVD = 14.79 Hz ± 2%
(Internal Master clock = 80.00 MHz,
Pixel clock = 40.00 MHz)
100L Partial Scan:
fHD = 30.769 KHz ± 2%
fVD = 27.97 Hz ± 2%
500L Partial Scan:
fHD = 30.769 KHz ± 2%
fVD = 49.63 Hz ± 2%
250L Partial Scan:
fHD = 30.769 KHz ± 2%
fVD = 79.92 Hz ± 2%