JAI TM/TMC-4200CL Security Camera User Manual


 
Page 51
Serial Communication Kit
TM/TMC-4200CL Series Progressive Scan Cameras
TABLE 8. TM-4200CL Command Response Table
Command Parameter
End of
Cmd Ack. Response Description
:SGE= X <cr> :o<cr> Set Digital Output Interface
(X = 0 CameraLink, X = 1 GigE)
:CCD= X <cr> :o<cr> CCD information (X = 1)
:PuLX X <cr> :o<cr> Password (X = 1 Administrator, X
= 0 Users)
Note: If a command is not accepted for any reason, the camera will return a “nack”
response. “:e” <cr> *Not available yet.
Command Parameter End of Cmd Description
Byte 1, 2 Master Gain Master Gain (H'0000 - H'0FFF: -3dB - +12dB)
Byte 3, 4 R Channel Fine
Gain
R Channel Fine Gain (H'0000 - H'0FFF)
Byte 5, 6 Master Offset Master Offset (H'0000 - H'0FFF)
Byte 7, 8 R Channel Fine
Offset
R Channel Fine Offset (H'0000 - H'0FFF)
Byte 9 Function Flag 0
Bit 0 Scan Area 0 0000=2048x2048 0001=2048x1000
0010=2048x500 0011=2048x250
Bit 1 Scan Area 1 0100=2x2 binning of 2048x2048 1111=User
Programmable Scan Area
Bit 2 Scan Area 2 1000=Digital Zoom x1 1001=Digital Zoom x2
Bit 3 Scan Area 3 1000=Digital Zoom x3 1001=Digital Zoom x4
Bit 4 Rsvd
Bit 5 Rsvd
Bit 6 Pixel Output
Order 0
00=<---<--- 01<=<------>
Bit 7 Pixel Output
Order 1
10=<<------
Byte 10 Function Flag 1
Bit 0 Shutter 0 Continuous Mode: 0000 - 1001=Continuous pre-
set shutter 0 - 9