JAI TM/TMC-4200CL Security Camera User Manual


 
Page 42
Functions and Operations
TM/TMC-4200CL Series Progressive Scan Cameras
6.4.7 PWC PIV Mode
The PWC PIV is based on PIV Fixed Exposure. In this mode, the first time exposure is controlled by the
pulse width of the external trigger, which is similar to PWC mode. The real exposure time of the first
image is equal to the pulse width of the external trigger.
The maximum trigger frequency in this mode is equal to 1/ (transfer time of two frames + exposure time
of the first image).
The minimum active period of the external trigger is 10 pixel clocks (250ns)
FIGURE 58. PWC PIV Timing Table.
TABLE 5. Timing Chart
Timing
Scan Mode
Unit
ABCDUTZ
tA dual
single
1300
2392
1300
2393
1300
2392
1300
2393
1300
2393
728
1274
1924
3016
Unit
tB dual
single
1024
2048
1024
2048
1024
2048
1024
2048
1024
2048
512
1024
256
512
Pixel Clock
tC dual
single
276
344
276
344
276
344
276
344
276
344
216
250
1668
2504
tD dual
single
176
176
176
176
176
176
176
176
176
176
166
166
800
800
tE dual
single
100
168
100
168
100
168
100
168
100
168
50
84
868
1704
tF 80 80 80 80 80 40 80
tG 224 224 224 224 224 112 224