FIGURE 55. Asynchronous Programmable External Trigger
6.4.5 Pulse Width Control Mode
In Pulse Width Control (PWC) Mode, the exposure time is controlled by the external trigger. When an
external trigger is applied, one discharge signal (Vsub) is generated right after the active edge of the
trigger. The exposure starts when the discharge signal is in the off state. The exposure is off following
the trigger active off. Exposure time is controlled by the pulse width of the external trigger. Because the
CCD requires some overhead from trigger active off to the transfer gate event, the actual exposure time
is equal to:
Exposure Time = Pulse Width +20.6μs
Since one discharge signal (Vsub) is generated right after the active edge of the trigger, it is
asynchronous with LDV, and the discharge signal may happen during an active video transfer period,
visible reset noise may show in the current image. To avoid reset noise, the maximum trigger frequency
in PWC mode should be less than 1/ (exposure time + one frame transferring time).
The minimum active period of the external trigger is 5μs. Theoretically, the maximum active period of
the external trigger is unlimited. But, since images obtained at 25
o
C are often very degraded due to
thermal noise, it is recommended the active period of the external trigger be no longer than one second.