Linking the unit with the switcher
Bus setting
From the [SETUP] menu, select [SW LINK] and display
[BUS]. Then set the material (AUX, PVW, PinP or KEY) to be
sent to the switcher.
3.BUS
AUX
The materials set using this item are sent from the remote
camera to the switcher when the remote camera has
been selected using one of the unit’s CAMERA STATUS/
SELECTION buttons.
Control can also be exercised by assigning this setting to a
USER button.
Focus assist setting
From the [SETUP] menu, select [SW LINK] and display
[FASIST]. Then set On or Off.
4.FASIST
Off
When “On” is selected as the item setting, the images on the
multi view display output by the switcher are switched to the
images of the remote camera selected by the unit.
Control can also be exercised by assigning this setting to a
USER button.
CAM1
CAM1
MV ON
CAM1 ON
Camera information setting
From the [SETUP] menu, select [SW LINK] and display
[CAMSEL]. Then set On or Off.
5.CAMSEL
Off
When “On” is selected as the item setting, an icon appears
at the bottom left of the image of the remote camera
selected by the unit on the switcher’s multi view display.
When a remote camera has been selected, its information is
sent from the unit to the switcher.