Linking the unit with the switcher
OA tally setting
From the [SETUP] menu, select [SW LINK] and display
[TALLY_IP].Then set On or Off.
6.TALLY_IP
Off
When “On” is selected as the item setting, the unit receives
the tally information (tally ON/OFF) sent periodically from
the switcher through the network, and it sends the ON or
OFF instruction to the remote cameras in which changes
have occurred.
[ Concerning the tally information transferred through
the network]
After receiving the tally information (Input1 to Input5) from
the switcher through the network, the unit sends the ON or
OFF instruction to the remote cameras.
Based on the relationship between the image output (remote
camera) and image input (switcher) which have been set
using the unit’s menu, the remote camera to which the
tally instruction is sent in response to the tally information
received from the switcher is identified, the tally indicator
of that remote camera is lighted in red, and the tally ON
instruction is sent to the remote camera.
The Tally ON instruction is also sent to the remote cameras
which are not in the selected camera group.
AW-RP50AW-HS50
Input1
Input3
1 2 3 4 5
1 2 3 4 5
TALLY
CAM
IP RP50CAMNo
Input1 CAM1
Input2 CAM2
Input3 CAM3
Input4 CAM4
Input5 CAM5
GPI Input
Group 1
Group 2
In response to inputs 1 to 5 from GPI Input, tally indicators
CAM1 to CAM5 are lighted in red, and the tally ON
instruction is sent to the remote cameras concerned.
Only CAM1 to CAM5 serve as the GPI Input tally.This
means that when a camera group other than No.1 is
selected, the tally indicators will go off.
The following tally-related settings can be established using
the menu.
p Enabling/disabling the tally information instructions
sent over the network
If only the tally information from GPI is to be enabled,
from the [SETUP] menu select [SW LINK], set [TALLY-IP]
to Off, and disable the tally information instructions sent
over the network.
p Enabling/disabling the tally ON instructions sent to
the remote cameras
From the [CAMERA] menu, select [TALLY] and display
[TALLY]. Then set enable or disable for the tally ON
instructions to be sent to the remote cameras in response
to the tally requests from the GPI and over the network.
PAN/TILT lever control setting
This setting makes it possible to use the unit’s PAN/TILT
lever as the switcher’s control lever.
From the [SETUP] menu, select [SW LINK] and display
[CAMSEL]. Then set Self/SW.
7.P/T LEVER ▲
Self
When “Self” has been selected as the setting, the unit’s
PAN/TILT lever is used as the lever for operating the pan
and tilt functions of the remote cameras.
When “SW” has been selected, the following information is
sent to the switcher.
PAN/TILT lever: X, Y speed
ZOOM button: Size speed