Patton electronic 2120 Security Camera User Manual


 
62
configure eia232 interface rxbuflen
X
Receive buffer length <num char>.
configure eia232 interface stoplength
X
Sets the RS-232 Stop Length (in bits) of the serial interface.
Accessibility:
READ/WRITE
Default:
1 (bit)
Valid Entries:
1, 2
configure eia232 interface subnetcfg X
Sets the Subnet Mask used to conduct PPP or SLIP operations.
Accessibility:
READ/WRITE
Default:
255.255.255.0
Valid Entries:
Any in Subnet Mask format
Note Must match the Subnet Mask of the LAN used to conduct PPP
or SLIP operations.
configure eia232 nvt echoena X
Echo Enable
configure eia232 nvt endofrecordena X
End-Of-Record Enable
configure eia232 nvt linemodeena X
Line Mode Enable
configure eia232 nvt terminaltype X
Terminal Type
configure eia232 nvt timingmarkena X
Timing Mark Enable
configure eia232 nvt transmitbinaryena X
Transmit Binary Enable
configure eia232 ppp
Returns the PPP Help Menu
Accessibility:
N/A
Default:
N/A
Valid Entries:
N/A
Note Needs to be entered first in all "configure eia232 ppp" command
strings.
configure eia232 ppp dhcpena X
Permits DHCP client operations to obtain an IP address for PPP.
Accessibility:
READ/WRITE
Default:
no
Valid Entries:
yes, no