Patton electronic 2120 Security Camera User Manual


 
68
configure system manena X
Permits access to the Model 2120 Software Command System via a
remote Telnet session over the LAN.
Accessibility:
READ/WRITE
Default:
yes
Valid Entries:
yes, no
Note If disabled, access to the Model 2120 Software Command Sys-
tem can is only possible via the serial interface.
configure system maninactiveto
X
Sets the period of time (in minutes) that the 2120 will close an inactive
Telnet session.
Accessibility:
READ/WRITE
Default:
15 (minutes)
Valid Entries:
0 – 10080
Note Entering a 0 for this parameter will disable this feature and allow
a Telnet session for an unlimited period of time.
configure system manport X
Management port
configure system prompt X
Sets system command prompt.
Accessibility:
READ/WRITE
Default:
TS>
Valid Entries:
Any alphanumeric entry with a string size up to 32 bytes
Note The system prompt may be changed to uniquely identify multi-
ple 2120 units.
configure system subnetcfg X
Sets the Subnet Mask of the 2120 unit.
Accessibility:
READ/WRITE
Default:
255.255.255.0
Valid Entries:
Any in Subnet Mask format
Note Must match the Subnet Mask of the LAN that the 2120 unit is
connected to.
configure userdatabase
Returns User Database Help Menu.
Accessibility:
N/A
Default:
N/A
Valid Entries:
N/A
Note Needs to be entered first in all "userdatabase" command
strings.