Sony HDW-750CE Camcorder User Manual


 
Chapter 6 Maintenance
6
6-10
3 Perform operations of steps 4 and 5 explained in (5) Testing
external microphones.
When performing the operation of step 5 in (5) Testing external
microphones, if the audio level meters in the display panel and
audio level indicators in the viewfinder reflect the changing sound
level, the function of the XLR connection automatic detection works
correctly.
If it does not reflect the changing sound level, the function of the
XLR connection automatic detection is set to OFF. Set REAR XLR
AUTO to ON on the VTR MODE 1 page of the MAINTENANCE
menu.
If it does not reflect even after you set REAR XLR AUTO to ON,
the XLR connection automatic detection function does not work
correctly.
(7) Checking the functions of the user bits and time
code
1 Set the user bits as required.
For more information see 4-5-3 Setting the User Bitson page 4-37.
2 Set the time code.
For more information, see 4-5-1 Setting the Time Code on page 4-34.
3 Set the F-RUN/SET/R-RUN switch to R-RUN.
4 Press the VTR START button, and check that the tape starts and
that the counter indication changes.
5 Press the VTR START button again, and check that the tape stops
and that the counter indication also stops changing.