Menu List
123
Chapter 6 Menu and Detailed Settings
Auto Iris2
Makes settings related
to auto iris.
Iris Window 1/2/3/4/5/6/Var Selects the type of iris detection
window.
Var: Variable
Iris Window Ind On/Off Turns on or off the function that
displays a frame marker for the auto
iris detection window.
Iris Level –99 to ±0 to +99 Adjusts the level of the auto iris
target value.
Iris APL Ratio –99 to ±0 to +99 Adjusts the mix ratio of auto iris
detection peak value and average
value.
Iris Var Width 40 to 500 to 999 Adjusts the width of the detection
window when the setting of Iris
Window is VAR.
Iris Var Height 70 to 500 to 999 Adjusts the height of the detection
window when the setting of Iris
Window is VAR.
Iris Var H Position –479 to 0 to +479 Specifies the horizontal position of
the detection window when the
setting of Iris Window is VAR.
Iris Var V Position –464 to 0 to +464 Specifies the vertical position of the
detection window when the setting
of Iris Window is VAR.
Iris Speed –99 to ±0 to +99 Specifies the control speed (speed of
reaction to changes in the video).
(Larger values specify quicker
reaction times.)
Clip High Light On/Off Turns on or off the function that
disregards highlights and forces a
flatter reaction to high luminance.
Flicker Reduce
Makes settings related
to flicker reduction.
Reduces the flicker that
can occur when a
subject is shot under a
light source with a
periodically varying
brightness, such as
fluorescent lights, due
to the relationship with
the camcorder’s
recording frame rate.
Mode Auto/On/Off Enables or disables flicker
reduction.
On: Always enabled.
Auto: Enabled when flicker is
detected.
Off: Disabled
Frequency 60Hz/50Hz Set to the frequency of the lighting
fixture that is causing the flicker.
(The factory default setting is 50 Hz
when the Country setting is
“PAL Area”, 60 Hz when it is other
than “PAL Area”.)
Genlock
Makes settings related
to genlock.
H Phase(HD) –999 to ±0 to +999 Specifies the H phase of HD output
when genlock is enabled.
H Phase(SD) –99 to ±0 to +99 Specifies the H phase of SD output
when genlock is enabled.
Reference Internal/Genlock Displays the type of reference signal
used by the camcorder.
MAINTENANCE
Menu items Sub-item Settings Description