Avaya R300 Security Camera User Manual


 
DEFINITY Enterprise Communication Server Release 9
Getting Started with the Avaya R300 Remote Office Communicator
Issue 1
November 2000
Avaya R300 Installation and Upgrade
37Installing the Avaya R300
3
Wall-Mount the Interconnect unit:
The plywood and the hardware to mount the plywood are installer-provided.
1. Secure a ¾ inch (2 cm.) thick sheet of 24” (61 cm.) x 4” (10 cm.) plywood to the
wall using screws. At least one side of the plywood should be secured to a framing
timber (i.e., 2 x 4) in the wall.
2. Secure the Interconnect unit to the plywood using the screws included with the
Interconnect unit.
Connect the Avaya R300 and R300 Interconnect
module
On the Avaya R300:
1. Slide the ejector on the Combo Blade as far to the right as possible, then gently
slide the ejector back to the left. The ejector moves about 1/8” to the left and locks
(stops) to reveal connector pins. The ejector is now correctly positioned so you can
insert the 68-pin connector. (see Figure 12).
Figure 12. Ejector lock in connector insertion position
SEE MANUAL
CAUTION
LAN UTP WAN 1 WAN 2 WAN 3 CONTROL SERIAL
LNK DPLX
COL 100BT
TX
RX
.75”
(19 mm)
prdfmax LJK 103100