DEFINITY Enterprise Communication Server Release 9
Getting Started with the Avaya R300 Remote Office Communicator
Issue 1
November 2000
DEFINITY Administration for the Avaya R300
60Set up signaling group
4
Set up signaling group
Each Avaya R300 has its own listen port and signaling group. Set up a new trunk group, or
use an existing trunk group administered for H.323 signaling.
Instructions
Signaling Group
Set up the signaling group for remote office:
1. Type add signaling-group <signaling group number or next>and press
ENTER to display the Signaling Group screen.
Screen 15. Signaling Group
2. On the signaling group screen, fill in the following fields:
■ Group Type: type H.323.
■ Remote Office: type y.
■ Near-end Node Name: assign the node name assigned to the C-LAN that
supports this Avaya R300.
■ Far-end Node Name: type the node name assigned to the remote office.
■ Near-end Listen Port: type a port number in the 5000-9999 range.
■ Far-end Listen Port: type 1720.
3. Press
ENTER to save your changes.
add signaling-group 6 Page 1 of 5
SIGNALING GROUP
Group Number 6 Group Type: H.323
Remote Office? y Max Number of NCA TSC: ___
Max number of CA TSC: ___
Trunk Group for NCA TSC: ___
Trunk Group for Channel Selection: 6
Supplementary Service Protocol: _
Near-end Node Name: clan Far-end Node Name: remote office 6
Near-end Listen Port: 5001 Far-end Listen Port:1720
LRQ Required? _ Calls Share IP Signaling Connection? _
RRQ Required? y
Bypass If IP Threshold Exceeded? _
Direct IP-IP Audio Connections? _
Interworking Message: ________