Avaya R300 Security Camera User Manual


 
DEFINITY Enterprise Communication Server Release 9
Getting Started with the Avaya R300 Remote Office Communicator
Issue 1
November 2000
Avaya R300 Administration
88Resetting the Avaya R300
5
When you upload this remote configuration information, keep in mind the following:
The Avaya R300 reads Dialout-Framed-User entries with the password ascend.
The Upd Rem Cfg command does not update the terminal-server banner or list of
Telnet hosts if the Remote Conf parameter is set to No.
If the Ascend-Authen-Alias attribute is defined in RADIUS, the Upd Rem Cfg
command also updates the Avaya R300 system name used when establishing PPP
calls.
NOTE:
In some cases, you might wish to update the Avaya R300 unit’s routing
tables when connecting to a user whose profile includes
Service-Type=Framed. In this case, set the Framed-Route attribute in
an incoming user profile to specify the user’s IP address and subnet mask in
the host_ipaddr and subnet_mask arguments. The route you specify
in this manner exists only during the time the call is online. When you enter
a nonzero router address for router_ipaddr and it is different from the
caller’s address, the static route of a dial-in frame persists even after the
connection goes offline.
Example: This example shows two RADIUS pseudo-user profiles defining global static IP routes:
route-1 Password=ascend Service-Type=Outbound
Framed-Route=10.0.200.33/29 10.0.200.37 1 n lala-gw-out
Framed-Route=10.0.200.50/29 10.0.200.37 1 n lala-gw-out
Framed-Route=10.0.200.47/29 10.0.200.49 1 n nana-gw-out
route-2 Password=ascend Service-Type=Outbound
Framed-Route=11.0.200.33/29 11.0.200.37 1 n zzz-gw-out
Framed-Route=12.0.200.47/29 11.0.200.49 1 n kk-gw-out
Resetting the Avaya R300
The Avaya R300 unit needs to be reset if you upload a new system software configuration
(not a new Avaya R300 profile configuration). You can reset the Avaya R300 unit in one
of the following ways:
Choose System >Sys Diag > Sys Rest from the VT100 menu interface.
Type reset at the diagnostic prompt.
Power cycle the unit by pulling the plug out of the outlet and then plugging it back
into the outlet.
NOTE:
Power cycling is not the preferred method of shutting down the Avaya R300.
The system does some clean-up with DEFINITY when reset using one of
the other methods.