Panasonic AW-HE870N Camcorder User Manual


 
- 25 -
System configuration (Connections)
Connection of a remote operation panel
When an SDI card (AW-HHD870) has been installed
First, turn off the power of all the equipment before proceeding with the connections.
Use the AW-PS510A for the AC adapter of the unit.
Connect the DC 12 V OUT socket on the AW-PS510A to the DC 12 V IN socket on the unit using the DC cable provided with
the AW-HE870.
Connect the CONTROL OUT TO CAMERA connectors [1] to [5] on the ROP with the I/F REMOTE connectors on the unit
through the connecting cables (optional accessory) AW-CA50T8 (or AW-CA50T9 + RS-422/RS-232C converter).
The distance between the ROP and the AW-CA50T8 (or AW-CA50T9 + RS-422/RS-232C converter) can be extended up to a
maximum of about 3280 ft. (1000 m) using a 10BASE-T (equivalent to UTP category 5) straight cable.
Zoom lens
Iris control
DC cable
provided with
AW-HE870
AC Adapter
AW-PS510A
AC Adapter
AW-PS510A
Monitor
Remote
Operation
Panel
AW-CB400
Cable
provided with
AC adapter
Control signal
10BASE-T straight cable
Video signal
Zoom/Focus control
Multi-Function
Controller
AW-RP655
Multi Hybrid
Control Panel
AW-RP555
AC Adapter
AW-PS510A
AC Adapter
AW-PS510A
or AW-CA50T9 +
RS-422/RS-232C
converter
AW-CA50T8
()