45
Metered-value difference indicator
Keep pressing the AEL button and the difference between the
metered exposure value and the exposure of the new composition
will be displayed on the viewnder LCD. This function can be used
to see if an object of very different brightness levels can be properly
photographed.
If the difference between the set value and the metered value exceeds
6EV, the viewnder LCD blinks “– u –” for underexposure and “– o – ”
for overexposure.
By turning the front or rear dial in the AE lock mode, you can change
the aperture and shutter speed value without changing the exposure
value that is set when entered into AE lock mode.
In the “P” mode (Program AE) mode, turning either the front or rear dial
shifts the program to “PH” and “PL.” When in “Av” (Aperture-priority
AE) or “Tv” Shutterpriority AE), turning one of the dials changes both
the aperture and shutter speed values.
NOTICE:
The way to cancel the AE lock can be
changed. Custom settings C-17.
Half-pressing of he shutter release
button can activate the AE lock
mode. Custom settings C-16.
The assignment of the AEL button
and AFL button can be swapped by
using Custom settings C-15.
Exposure compensation and auto-
bracketing function can be used
when the camera is in the AE lock
mode in normal operation or with the
mirror locked up.