M3099GX/GH OEM Manual 3-79
INTERFACE
Destination Table Size: 0100h(255 step)
The destination table size field specifies the range of output value to
Gamma Correction Table.
Gamma Correction Table Data:
The gamma correction table data transfers look up table for image
data to be scanned.
Example - 256 steps of grayscale
INPUT
OUTPUT
ORDER
DATA
0
00h
1
00h
2
00h
3
00h
4
00h
5
00h
6
00h
7
00h
8
00h
9
00h
10
D0
11
D0
12
D0
13
D0
14
D0
15
D0
16
D0
17
D0
…
…
263
D253
264
D254
265
D255
D0 to D255 can be any 0 to 255 value. Each data is one byte length.
Endorser Data
See ENDORSER Command.
SCAN Command
The SCAN command (Table 3.59) requests the target begin a scan
operation.
Table 3.59 SCAN Command
Bit
Byte
0
1
2
3
4
5
7 6 5 3 2 1 0
Operation Code (1Bh)
Reserved
Reserved
Transfer Length
Control
Logical Unit Number Reserved
4
#03.pm5 98.2.22, 1:33 PM79