Fujitsu C150-E049-02EN Photo Scanner User Manual


 
M3099GX/GH OEM ManualB-12
B3.15 Setting picking time
When you set the picking time, you must set as follows.
f At Screen 2, press [Mode 1] fifteen times to
go to the PICK TIMER screen. (Screen 30)
g Press [Mode 2] to see Screen 31. (The default
setting is 2 sec.)
h At Screen 31, press [Mode 1] until the digit
you want to change blinks. Then press [Mode
2] until the digit changes as you want. (The
specifiable range is from 0.5 to 99.5 sec. in
0.5 sec. step.)
i Press [Mode 1] and [Mode 2] at a time to see
Screen 30. The settings are stored to
EEPROM.
j When you close the setup mode, go to 9.
B3.16 Setting time-out limit
When you set the time-out limit, you must set as follows.
k At Screen 2, press [Mode 1] sixteen times to
go to the TIME-OUT SET screen. (Screen
32)
l Press [Mode 2] to see Screen 33. (The default
setting is 30 sec.)
m At Screen 33, press [Mode 1] until the digit
you want to change blinks. Then press [Mode
2] until the digit changes as you want. (The
specifiable range is from 1 to 1999 sec. in 1
sec. step.)
n Press [Mode 1] and [Mode 2] at a time to see
Screen 32. The settings are stored to
EEPROM.
o When you close the setup mode, go to 9.
<< SETUP MODE >>
PICK TIMER
Screen 30
<< SETUP MODE >>
X X . X S
Screen 31
<< SETUP MODE >>
TIME-OUT SET
TIME-OUT SET
X X X X S
Screen 33
Screen 32