3-60 M3099GX/GH OEM Manual
The window width field specifies the width of window in scan line
direction. The window width is measured using the target’s current
measurement unit divisor.
Window Length: 0 to 20736 [1/1200 inch]
The window length field specifies the length of the window in the
base line direction. The window length is measured using the target’s
current measurement unit divisor.
Note: The relation between X-Axis Resolution, Y-Axis Resolution,
X-Axis Upper Left, Y-Axis Upper Left, Window Width,
Window Length.
Upper Left X field value: ULX
Upper Left Y field value: ULY
Width field value: W
Length field value: L
X Resolution: XR
Y Resolution: YR
1) Maximum Scanning Area limitations
0 < (ULX+W) ≤ 14592 [1/1200 inch] for M3099GX
10368 [1/1200 inch] for M3099GH
0 < (ULY+L) ≤ 20736 [1/1200 inch]
2) Width and X Resolution limitation
9 ≤ (XR×W/1200) ≤ 4864 [dot] for M3099GX
3456 [dot] for M3099GH
3) Length and Y Resolution limitation
1 £ (YR×L/1200) ≤ 6912 [line]
4) Horizontal and Vertical limitation (M3099GX only)
if ( 13200(11") < (ULX+W) ≤ 14592 )
then 0 < (ULY+L) ≤ 19842(A3 length) ;
Brightness: 0 to 255
The brightness field specifies the level of brightness used to scan the
object. A value of zero specifies the default brightness. Any other
value indicates a relative brightness setting with 255 being the
highest setting, one being the lowest setting, and 128 being the
nominal setting.The brightness effects for Halftone image.
#03.pm5 98.2.22, 1:32 PM60