3-14 M3099GX/GH OEM Manual
Power-On to Selection Time
The recommended maximum time from power application until an
SCSI target is able to respond with appropriate status and sense data
to the TEST UNIT READY, INQUIRY, and REQUEST SENSE
commands.
Reset to Selection Time
The recommended maximum time after a hard RESET condition
until an SCSI target is able to respond with appropriate status and
sense data to the TEST UNIT READY, INQUIRY, and REQUEST
SENSE commands.
Reset Hold Time
The minimum time for which RST is asserted. There is no
maximum time.
Selection Abort Time
The maximum time that a target (or initiator) shall take from its
most recent detection of being selected (or reselected) until asserting
a BSY response. This time-out is required to ensure that a target (or
initiator) does not assert BSY after a SELECTION (or
RESELECTION) phase has been aborted. This is not the selection
time-out period; see ANSI SCSI-2 6.1.3.1. and ANSI SCSI-2
6.1.4.2. for a complete description.
Selection Time-out Delay
The minimum time that a SCSI device should wait for a BSY
response during the SELECTION or RESELECTION phase before
starting the time-out procedure. Note that this is only a
recommended time period.
#03.pm5 98.2.22, 1:31 PM14