M3099GX/GH OEM ManualB-10
<< SETUP MODE >>
SCSI-ID SET
Screen 24
SCSI-ID SET
5
Screen 25
<< SETUP MODE >>
PRODUCT-ID SET
PRODUCT-ID SET
X X X X X X
Screen 27
Screen 26
B3.10 Reset of endorser
When you reset the number to the initial number, you must see Section
A2.4 of Appendix A.
B3.11 Reset of ink counter
When you reset the ink counter, you must see Section A2.5 of Appendix A.
B3.12 Setting SCSI-ID
When you set the SCSI-ID, you must set as follows.
31 At Screen 2, press [Mode 1] twelve times to
go to the SCSI-ID SET screen. (Screen 24)
32 Press [Mode 2] to see Screen 25. (The default
setting is “5”.)
33 At Screen 25, the SCSI-ID is from 0 to 7
each time you press [Mode 1].
34 Press [Mode 2] to see Screen 24. The settings
are stored to EEPROM.
35 When you close the setup mode, go to 9 .
B3.13 Setting Product-ID
When you set the Product-ID, you must set as follows.
36 At Screen 2, press [Mode 1] thirteen times to
go to the PRODUCT-ID SET screen.
(Screen 26)
37 Press [Mode 2] to see Screen 27. (The default
setting is “M3099GH” in case of M3099GH
and “M3099G” in case of M3099GX.)