6 - 10
6-1-7 Creating Reference Data
Start the setup program referring to “6-1-6 Starting and Terminating Reference Data Creation
Program”. For subsequent operation, operate the PC mouse while watching the PC monitor screen.
Information:
It takes approx. 20 minutes to create reference data.
The following shows the times required for each item:
Matrix: Approx. 10 minutes
White Balance: Approx. 10 minutes
White Balance Abs: Approx. 30 seconds
Preparation:
1) Point at light box without chart, filling the screen.
2) Prepare the C12 light balancing filter (step-up rings):
Attach it during setup.
Procedure:
1) Choose MATRIX on the SETUP MENU screen.
2) Click the EXECUTE button on SETUP MENU screen to
start setup.
3) The ATTACH THE FILTER dialog will appear during
setup. Attach the C12 light balancing filter over the lens
of DVD video camera/recorder, and then click the OK
button in ATTACH THE FILTER dialog.
4) The REMOVE THE FILTER dialog will appear during
setup.
Remove the C12 light balancing filter from the lens of
DVD video camera/recorder, and then click the OK
button in REMOVE THE FILTER dialog.
After that, the ATTACH THE FILTER dialog and
REMOVE THE FILTER dialog may occasionally appear:
Reattach the C12 light balancing filter and remove it
each time.
5) When setup is complete, the SETUP FINISHED dialog
will appear: Click the OK button in
dialog to restore the SETUP MENU screen.
When setup is complete with the C12 light balancing
filter attached, remove the C12 light balancing filter.
6) Choose WHITE BALANCE on the SETUP MENU
screen.
7) Repeat steps 2)-5).
SETUP MENU screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
Matrix
EXECUTE
RETURN
SETUP MENU
White Balance Abs
White Balance
2
1
ATTACH THE FILTER dialog
REMOVE THE FILTER dialog
OK
Attach The Filter.
CHECK
!
3
OK
Remove The Filter.
CHECK
!
4
SETUP MENU screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
Matrix
EXECUTE
RETURN
SETUP MENU
White Balance Abs
White Balance
6
7
SETUP FINISHED dialog
FINISHED
SETUP FINISHED.
OK
5
Adjustment > Creating Reference Data