Hitachi DZ-MV580E DZ-MV580E(AU) DZ-MV580E(SW) DZ-MV580E(SWH) DZ-MV580E(UK) DZ-MV550E DZ-MV550E(AU) DZ-MV550E(SW) DZ-MV550E(SWH) DZ-MV550E(UK) Camcorder User Manual


 
6 - 40
Adjustment > Adjustment Procedure
7) Connect the oscilloscope CH1 to “LCD-B (pin 7)” of
Skylark Connection jig.
8) Use the same procedure as in step 3) to equalize levels a
and b of the waveform. (See Fig. 6-4-11)
9) After step 8) is complete, be sure to click the NEXT
button, and then proceed with the SUB BRIGHT BLUE
ADJUSTMENT screen.
10) Use the same procedure as in step 3) to equalize levels c
and d of the waveform.
11) After step 10) is complete, be sure to click the SAVE
button.
12) When save is complete, the ADJUSTMENT FINISHED
dialog will appear: Click the OK button in dialog to
restore the LCD ADJUSTMENT MENU screen.
13) Click the RETURN button in LCD ADJUSTMENT
MENU to restore the ADJUST MENU screen.
SUB BRIGHT BLUE ADJUSTMENT
screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
NEXT
RETURN
SUB BRIGHT BLUE ADJUSTMENT
UP
DOWN
CONNECTION
11
10
SUB CONTRAST BLUE ADJUSTMENT
screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
SAVE
RETURN
SUB CONTRAST BLUE ADJUSTMENT
UP
DOWN
CONNECTION
9
8
ADJUSTMENT FINISHED dialog
FINISHED
ADJUSTMENT FINISHED.
OK
12