Sanyo VCC-6974 Security Camera User Manual


 
USING THE MENU SCREEN OPTION/RS-485
ADDRESS setting
If the ADDRESS setting on the screen is 0, this means that the camera’s RS-485 address is
currently set to 0. If the address is changed using the address setting switches at the side of the
camera as shown in the illustration, the new address will be displayed on the screen.
TERMINATE setting
The DIP switches need to be set when a computer, special controller, etc. connected to the
RS-485 connectors is used to control the camera. Make sure to turn the camera power off
before setting the DIP switches.
About SW No.
1-7: To setup the camera address (only when using the RS-485 connector).
Switch 1 is the least significant bit (LSB) and switch 7 the most significant bit (MSB) (Down: 0,
Up: 1). This setting is done according to a binary code.
8: To setup the termination (only when using the RS-485 connector).
OFF side (down): Not terminated
ON side (up): Terminated
Returning the values to the default settings
Press the CURSOR (l, then d or c) button to change the PRESET setting to ON, then press
the SET button.
When finished
Press the CURSOR (l) button to select BACK (it will flash) at the bottom of the screen. Then
press the CURSOR (d or c) button to change BACK to END, and press the SET button.
To return to the previous screen, select BACK then press the SET button.
MENU FOR RS-485
BAUD RATE 19200
ALARM ON
ADDRESS 0
CURSOR
SET
MENU BACK
CURSOR
SET
MENU END
(ADDRESS SET)
ON
12345678
ON
OFF
TERMINATER ON/OFF
L53R4/US GB 1999, 12, 7